SIDNs
S00011Class1diagnostic(C1D)
Theparametercontainserrorgroupsthattriggera"driveshutdown"error.
Attributes
Name Value
Format Binary
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue
Unit
ChangeableinEtherCATstate No
Cyclictransfer AT
Deviceparameter No
Relatedtointerfacerevision No
Ifanerrorisdiagnosedinthedrive,thisresultsinanerrorresponseandtheerrorbitisset,asdescribed
below.Inaddition,errorbit13issetbyS00135to"1"andisonlyresetto"0"bythedrivewhenthedrive
hasexecutedthecommandS00099andanyerrorshavebeencleared.
Topreciselyidentifytheerror,readtheerrormemory.
Bitpattern:
Bit Meaning
0 Overloadshutdown
Overloadshutdown
0=noerror
1=error
1 Amplifierovertemperatureshutdown
Amplifierovertemperatureshutdown
0=noerror
1=error
2 Motorovertemperatureshutdown
Motorovertemperatureshutdown
0=noerror
1=error
3 Coolingerrorshutdown
Coolingerrorshutdown
0=noerror
1=error
4 Controlvoltageerror
Controlvoltageerror
0=noerror
1=error
5 Feedbackerror
Feedbackerror
0=noerror
1=error