Product Description
2.4.1 USB Interfaces (X112, X113)
The two USB interfaces (X112, X113) are used for connecting peripheral devices with USB connection.
USB2.0 standard is supported.
2.4.2 ATX Push-button
The Industrial PC is switched on via the push-button (ATX) (Power on).
2.4.3 Reset-button
The reset-button enables re-booting the Industrial PC.
2.4.4 Status LEDs
• The LED HDD is illuminated at HDD access.
• The LED PWR is illuminated when power is on.
• The LED FB is a multi color LED and shows the status of fieldbus and TwinCAT:
Color LED FB Description
red TwinCAT STOP
blue TwinCAT CONFIG
blue/ red blinking TwinCAT CONFIG with Bus Error
green TwinCAT RUN
green/ red blinking TwinCAT RUN with Bus Error
2.5 Rear view of the C5210
The C5210 Industrial PC is fitted with a 100-240 V, 50-60 Hz full range power supply unit.
Optional a 24 V
DC
power supply unit with UPS is available.
2.5.1 100-240V
AC
Full Range Power Supply
Rear view C5210
with 100-240V
AC
full range
power supply
main switch
batter
o
tional fieldbus
interfaces
PCIe module slots
ower su
l