C1300 VME to II/O Interface Unit Beckhoff II/O-System
Page 8 of 44 Version : 2.01 Date : 18.12.95
The contents of the telegram is mainly organized for each byte.
AD0 - AD7 create the address field.Using this address field up to 254 modules can be
addressed ( Address 00h and 0fh are reserved. ).
CR0 - CR3 define the type of telegram. Following functions can be defined in the telegram:
CR3 CR2 CR1 CR0 Function Beschreibung
0000
READ
The modul addressed writes the entry data into
the Data fields D0 - D3 .
0001
READ/WRITE
The modul addressed writes the entry data into
the Data fields D0 - D3 and loads the
Ausgangsinformation.
0010
ADDRESS INITIALIZITION
The module addressed loads the contents of D0
as a module address und sets D0 = 0.
0100
ADDRESS CHECK AND
COUNT COMMAND
Each module passed increases the contents of
D0 by 1. The module addressed is loads the
contents from D0 into D3.
1001
LOW INTENSITY
COMMAND
The module addressed reduces the transmission
intensity by 20%.
picture 3:Controlfield
Byte D0 - D3 contain the actual Data to use. The processing of this data is determined by the
controll field.
The last Byte in a telegram contains two spare bits and 6 bits to create a CRC checksum. The
contents, having a length of 50 bits, achieves a Hamming distance of d = 3.