Page 1

LIGHTBUS Bus Terminal Controller BC2000 Technical Documentation Version 1.1 2006-11-06

Page 2

Basic Principles 9 BC2000 Structure of the potential levels in the bus terminal system 24VDCPeripheral levelBus couplerBus terminalsTerminal bu

Page 3 - Table of Contents

Basic Principles BC2000 10 The bus terminal controller can be made to enter the normal operating state by switching it on again on

Page 4 - Foreword

Basic Principles 11 BC2000 Insulation testing PE power contacts inserted into the terminal without any force.

Page 5 - Safety Instructions

Basic Principles BC2000 12 PLC data BC 2000 Programmability via the programming interface (TwinCAT BC/TwinCAT) or via optical fibre ring

Page 6 - Basic Principles

Basic Principles 13 BC2000 Error code Error argument Description Remedy Persistent, continuous blinking EMC problems - Check power supp

Page 7

Basic Principles BC2000 14 PLC LED If the PLC LED lights, the program has started on the BC2000. The LED flashes while a boot project is

Page 8 - II/O-Lightbus

The Beckhoff BC2000 Lightbus Coupler 15 BC2000 The Beckhoff BC2000 Lightbus Coupler Introduction to the Beckhoff Lightbus System The Beckho

Page 9 - Galvanic isolation

The Beckhoff BC2000 Lightbus Coupler BC2000 16 Master interfaces supporting the bus terminal controller are the PC cards C1220 as from Ve

Page 10 - Peripheral level

Settings in the TwinCAT System Manager 17 BC2000 Settings in the TwinCAT System Manager Basic Settings The basic properties of the bus

Page 11 - BECKHOFF

Settings in the TwinCAT System Manager BC2000 18 PLC Cycle Time PLC Cycle Time The PLC cycle time determines the program’s repetiti

Page 12

Please note the following Target group This description is only intended for the use of trained specialists in control and automation enginee

Page 13

Settings in the TwinCAT System Manager 19 BC2000 Remanent Variables Retained or remanent variables are data that retain their value

Page 14

Settings in the TwinCAT System Manager BC2000 20 Program Download via the RS232 Interface Every bus terminal controller offers the possib

Page 15

Settings in the TwinCAT System Manager 21 BC2000 registers of the bus terminal controller and the terminals. PLC Runtime System Port 800 The

Page 16

Settings in the TwinCAT System Manager BC2000 22 Registers of the Bus Terminal Controller Port 100 The port number in the BC2000 for register

Page 17

Settings in TwinCAT PLC 23 BC2000 Settings in TwinCAT PLC Some of the settings for the BC2000 are only possible in PLC Control. Th

Page 18 - Basic Settings

Settings in TwinCAT PLC BC2000 24 Coupler Options The maximum size of the program memory and of the data memory can be set in PLC Control

Page 19 - PLC Variables

Appendix 25 BC2000 Appendix Absolute Addressing in the BC2000 Input Output KL3002 %IB0 Status KL3002 %QB0 Control KL3002 %IB1 E

Page 20 - Terminal Bus Update

Index BC2000 26 Index A ADS Functions 18 Assembly 8 B Background time 16 BC2000 dimensions 8 Blink code 10 Boot project 21 C Configuratio

Page 21 - ADS Functions

Support and Service 27 BC2000 Support and Service Beckhoff and their partners around the world offer comprehensive support and service, makin

Page 22 - PLC Runtime System

Table of Contents BC2000 2 Table of Contents 1. Foreword 3 Notes on the documentation 3 Liability Conditions 3 Delivery conditions 3 Copyri

Page 23 - Diagnostics in the BC2000

Foreword 3 BC2000 Foreword Notes on the documentation This description is only intended for the use of trained specialists in control and a

Page 24 - Settings in TwinCAT PLC

Foreword BC2000 4 Safety Instructions State at Delivery All the components are supplied in particular hardware and software config

Page 25 - Coupler Options

Basic Principles 5 BC2000 Basic Principles Description of the BC2000 The BC2000 is a slave with PLC functionality. It has a fieldb

Page 26 - Appendix

Basic Principles BC2000 6 Display of the channel state functions limits the number of unused channels to a maximum of one per function.

Page 27 - BC2000 26

Basic Principles 7 BC2000 Bus terminal controllers for various fieldbus systems Various bus terminal controllers can be used to couple

Page 28 - Support and Service

Basic Principles BC2000 8 Power contacts Spring contacts on the side On the right hand face of the bus terminal controller there are three s